Kenco-engineering KEFS Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Kenco-engineering KEFS. Kenco Engineering KEFS User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 4
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
KENCO ENGINEERING COMPANY
P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4406
www.kenco-eng.com e-mail: [email protected]
MODEL KEFS LIQUID LEVEL FLOAT SWITCH
INSTALLATION / OPERATION INSTRUCTIONS
PRINCIPLE OF OPERATION
The Model KEFS uses a float to determine the presence or absence of liquid at the process connection. The float arm assembly
consists of a float at one end and a magnet at the other. As the level rises, the float rises, and the magnet falls. The magnet
actuates a second magnet on the other side of the pressure boundary. This second magnet causes the switch to change state.
The pressure boundary contains no seals; it is a solid stainless steel barrier that passes a magnetic field, but no liquids. It is
impossible for the process liquid to enter the switch enclosure through this barrier.
The electrical contacts consist of a microswitch that can be either a Single-pole, Double-throw (SPDT) or Double-pole, Double-throw
(DPDT) Configuration. The SPDT Switch is available with either a 5 Amp or 8 Amp current load. The DPDT is available with a 5
Amp/30Vdc current load (See Switch Types and Ratings in the Product Specifications for more details).
MODEL DESCRIPTION
KEFS - - - -
Process Connection
Switch Rating
Temperature Rating
Wetted Parts
* High
temperature option only available with 5A SPDT switch
(58639 Rev B)
Temperature Rating Wetted Parts
Description Code Description Code
Standard
blank
303 SS (std.)
blank
High* 400 316 SS S6
Process Connection Switch Rating
Description Code Description Code
1½” NPT N/A 5A SPDT SPDT5
2” NPT (std.) 2 4A DPDT DPDT4
8A SPDT SPDT8
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 ● PHONE: (918) 663-4406 FAX: (918) 663-4406 www.kenco-eng.com e-mail: info@kenco-eng.

Pagina 2

SWITCH DIMENSIONS INSTALLATION Unpack the switch carefully. Inspect the unit(s) for damage. Report any damage to carrier immediately. Check the

Pagina 3

WIRING TERMINALS CM = Common; NC = Normally Closed; NO=Normally Open 1 = Used in both SPDT and DPDT Switches; 2 = Used in DPDT Switches Only 1.

Pagina 4

8. Carefully reinstall the Switch Housing Cover; BE CAREFUL not to pinch the wires PRODUCT SPECIFICATIONS Description Specification Spec

Comentarios a estos manuales

Sin comentarios