Kenco-engineering SmartSonic Transmitter (Remote) Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Sensores Kenco-engineering SmartSonic Transmitter (Remote). Kenco Engineering SmartSonic Transmitter (Remote) User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 37
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Page 1
KENCO ENGINEERING COMPANY
P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480
www.kenco-eng.com e-mail: [email protected]
SMARTSONIC REMOTE ACOUSTIC WAVE LEVEL / OPEN CHANNEL FLOW TRANSMITTER
INSTALLATION / OPERATION INSTRUCTIONS
TABLE OF CONTENTS
1. GENERAL DESCRIPTION ............................................................. 2
2. PRINCIPLE OF OPERATION ......................................................... 2
3. MODEL DESCRIPTION .................................................................. 2
4. SPECIFICATIONS .......................................................................... 2
5. INSTALLATION .............................................................................. 2
6. DIMENSIONS.................................................................................. 3
7. MOUNTING GUIDELINES .............................................................. 4
8. MOUNTING INSTRUCTIONS ......................................................... 4
9. WIRING ........................................................................................... 5
Wiring Connections....................................................................... 6
10. CALIBRATION................................................................................ 8
Accessing the Main Menu............................................................. 10
11. SETTING THE MAIN MENU OPTIONS .......................................... 11
12. OPEN CHANNEL FLOW MEASUREMENT ................................... 22
13. ADDITIONAL FEATURES .............................................................. 30
Additional Features Program List................................................ 31
14. TROUBLESHOOTING .................................................................... 37
Vista de pagina 0
1 2 3 4 5 6 ... 36 37

Indice de contenidos

Pagina 1 - KENCO ENGINEERING COMPANY

Page 1 KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 ● PHONE: (918) 663-4406 FAX: (918) 663-4480 www.kenco-eng.com e-mail: info@ken

Pagina 2

Page 10 Accessing the Main Menu This section describes the procedure for accessing the SmartSonic Main Menu. The main screen (see Page #7) is accesse

Pagina 3 - (Sensor)

Page 11 SETTING MAIN MENU OPTIONS The following functions are available in the SmartSonic Main Menu: NOTES: After you select any option the “Tank G

Pagina 4

Page 12 Setting the Measurement Mode This function is used to select the units used for the display. The following measurement options are available:

Pagina 5

Page 13 Volume and Totalization should only be configured after setting the Volume/Totalization options in the Additional Features Section later in th

Pagina 6

Page 14 Press / Action Display Description Press ENT when “Relay” is flashing to enter relay setup or For example: Cycle betw

Pagina 7

Page 15 Press / Action Display Description Press ENT when “Relay” is flashing to enter relay setup or For example: Cycle betw

Pagina 8

Page 16 Press / Action Display Description or and Move to Relay #4, then press ENT. Choose Err En to enable er

Pagina 9

Page 17 Setting the 20mA and 4mA Values SmartSonic enables you to set Distance, Level, Volume or Flow values to be used as 20mA and 4mA settings. The

Pagina 10 - Scan distance

Page 18 NOTES: Whenever the tank height is required, you should enter the distance from the face of the sensor to the bottom of the tank. In order

Pagina 11

Page 19 NOTE: STORAGE I and STORAGE II are not suitable for measuring liquids containing foam, since these modes cannot perform signal proces

Pagina 12

Page 2 GENERAL DESCRIPTION The SmartSonic Acoustic Wave Transmitter is designed for high accuracy level measurement of a variety of liquids. The Smar

Pagina 13

Page 20 Setting the Scan Distance Values (False Targets) Up to eight interfering signals (false echoes) can be located b

Pagina 14

Page 21 Press / Action Display Description or Move to AUTO CAL (flashing). and sim

Pagina 15

Page 22 OPEN CHANNEL FLOW MEASUREMENT This section describes how to set the flow measurement parameters for Open Channel Flow measurement. It also co

Pagina 16

Page 23 The flume/weir type code methodology used when setting up open channels is based on three digits: X .(E/U) FF Where: X refers to the part

Pagina 17

Page 24 Flumes / Weirs – U.S. Standard (dimensions are in inches unless otherwise indicated) Type 1 (X) – Rectangular Suppressed Sharp-Crested Weir

Pagina 18

Page 25 Type 4 (X) – V-notch (Triangular) Sharp-Crested Weir Type 5 (X) - Parshall Flume Type 6 (X) – Palmer-Bowlus Flume

Pagina 19 - Or

Page 26 Type 7 (X) – H-Flume Type 8 (X) – Leopold-Lagco Flume Code (FF) Flume Size Measurement Point 01 6 1.96 02

Pagina 20

Page 27 Flumes / Weirs – European (dimensions are in centimeters unless otherwise indicated) Type 1 (X) – Rectangular Suppressed Sharp-Crested Weir

Pagina 21 -

Page 28 Type 4 (X) – V-notch (Triangular) Sharp-Crested Weir Type 5 (X) – Khafagi-Venturi Flume Type 6 (X) – Pa

Pagina 22 - Flashes for 5

Page 29 Type 7 (X) – Palmer-Bowlus Flume Type 8 (X) – H-Flume Type 9 (X) – Neyrpic-Venturi Flume / Long Base Weir

Pagina 23

Page 3 DIMENSIONS - INCHES 3.15 3.31 9.68 7.87 3.26 2.87 2.28 2.75 Transducer (Sensor) 2.83 0.59 4.88 2.56 0.55 1” NPT Mountin

Pagina 24

Page 30 ADDITIONAL FEATURES This section describes the functions available in SmartSonic Remote's additional menu. The additional menu functions

Pagina 25

Page 31 Selecting an Indication Mode Using function Pr 0, you can modify the SmartScan default display to show indications for volume, t

Pagina 26

Page 32 Manually Inserting Strapping Table Values The Pr 1 function enables you to manually create a strapping table of distance points for either vo

Pagina 27

Page 33 Semi-automatic Inserting Strapping Table Values The Pr 2 function enables you to create a strapping table for distance/volume values using

Pagina 28

Page 34 Entering a Coefficient for Readings The Pr 3 function enables you to enter a coefficient value, K, which can be used for three different op

Pagina 29

Page 35 Configuring Height for a Cone Bottom Tank The Pr 5 function enables you to enter the cone height for tanks that have a conical base. This m

Pagina 30

Page 36 Defining the 4-20mA Error Signal (3.7mA or 22mA) The Pr 6 function allows you to define whether the following signal error indications Near

Pagina 31

Page 37 TROUBLESHOOTING This chapter describes the error messages displayed when an illegal value is entered for a SmartSonic Remote function. If an

Pagina 32

Page 4 MOUNTING GUIDELINES MOUNTING INSTRUCTIONS Precautions: • Ensure that the sensor is mounted in an area tha

Pagina 33

Page 5 Mounting the Sensor to a Flange 1.) Feed the free end of the sensor cable through the 1” NPT threaded connection on the flange. Feed the cabl

Pagina 34

Page 6 Wiring Connections In order to connect the wiring, remove the ribbed faceplate on the front of the electronics, using a 7/64” (3mm) Allen wren

Pagina 35

Page 7 Wiring the Digital and Analog Communication Cables SmartSonic data can be monitored on a PC or PLC via RS-485 (MODBUS RTU) digital communicatio

Pagina 36

Page 8 CALIBRATION This section explains how to set up and calibrate the SmartSonic for accurate measurement monitoring using the basic menu options.

Pagina 37 - TROUBLESHOOTING

Page 9 Tank Terminology Default Screen As soon as SmartSonic is fully installed and powered on, the LCD displays the default screen. The d

Comentarios a estos manuales